Inyathelo ngalinye line-QC injineli elandelayo:
1.Khetha iiseli zebhetri ezifanelekileyo, kwisicelo esahlukileyo kunye nobukhulu, sinokukhetha iiseli zebhetri ezifanelekileyo, iiseli ze-cylindrical okanye iiseli zeprismatic, ngokukodwa iiseli ze-LiFePO4.Kuphela kusetyenziswa iiseli ezisanda kufakwa.
2.Ukwahlulahlula ibhetri ngomthamo ofanayo kunye ne-SOC, qinisekisa ukuba iipakethi zebhetri zisebenza kakuhle.
3.khetha i-busbar yoqhagamshelo olusebenzayo lwangoku, ukuwelda iiseli ngendlela elungileyo
4.Ukudityaniswa kwe-BMS, hlanganisa i-BMS efanelekileyo kwiipakethi zebhetri.
5.Iipakethi zebhetri zeLiFePO4 zifakwe kwiCase yentsimbi ngaphambi kovavanyo
6.Uvavanyo lwemveliso
7.Imveliso imile kwaye ilungele ukupakishwa
8.Ibhokisi lenkuni Ukupakisha okunamandla
Imijikelo engama-4000 @80% DoD ngexabiso eliphantsi ngempumelelo lilonke leendleko zobunini
Iibhetri zokugcinwa okuphantsi kunye nekhemistri ezinzileyo.
IBattery Management System (BMS) ibandakanyiwe ngokuchasene nokuxhatshazwa.
ukuya kuthi ga kwiinyanga ezi-6 enkosi kwiqondo eliphantsi kakhulu lokuzikhupha (LSD) kwaye akukho mngcipheko wesulphation.
Yonga ixesha kwaye wandise imveliso kunye nexesha eliphantsi lokubulela kwintlawulo ephezulu / ukusebenza kakuhle kokukhupha.
Ilungele ukusetyenziswa kuluhlu olubanzi lwezicelo apho ubushushu be-ambient buphezulu ngokungaqhelekanga: ukuya kuthi ga ku +60°C.
Iibhetri zeLithium zibonelela ngakumbi nge-Wh/Kg ngelixa zikwafikelela kwi-1/3 yobunzima be-SLA elinganayo.
1.ibhetri yenkqubo yokugcina amandla ekhaya.
2.telcom amandla backup.
3.off igridi yesixokelelwano selanga.
4.I-backup yokugcina amandla.
5.Ezinye isicelo sogcino lwebhetri.
umyinge woqwalaselo olwahlukileyo
*** Qaphela: Njengoko iimveliso zihlaziywa rhoqo, nceda uqhagamshelane nathi ngeenkcukacha zamva nje.***
Telecom amandla backup
Ukugcinwa kwamandla elanga
Indawo yokugcina impahla
Ibhetri yeLiFePO4 | Umzekelo | 48500 | 48400 (ukhetho) | 48300 (ukhetho) |
Umbane woMbane | 51.2 V | |||
Umthamo oqhelekileyo | 500Ah | 400Ah | 300 Ah | |
Amandla | 25600 Wh | 20480Wh | 15360 Wh | |
Unxibelelwano | CAN2.0/RS232/RS485 | |||
Ukuchasa | ≤50 mΩ @ 50% SOC | |||
Ukusebenza kakuhle | >96% | |||
Intlawulo eCetyisiweyo yangoku | 0.2C | |||
Ukukhutshwa okuQhubekayo okukhulu ngoku | 0.2C | |||
Ubuninzi bamandla omthwalo | 4KW/modyuli | |||
Kucetyiswa ukuTshaja iVoltage | 57.6V | |||
I-BMS Charge Cut-Off Voltage | <58.4 V (3.65V/Iseli) | |||
Phinda uqhagamshele i-Voltage | >57.6 V (3.6V/Cell) | |||
Ukulinganisa amandla ombane | <57.6 V (3.6V/Iseli) | |||
Ukulinganisa amandla ombane avulekileyo | 55.2V (3.45V/Iseli) | |||
Ukuqhawulwa kombane ophantsi ocetyiswayo | 44 V (2.75V/Cell) | |||
I-BMS Discharge Cut-Off Voltage | >40.0V (2s) (2.5V/Cell) | |||
Phinda uqhagamshele i-Voltage | >44.0 V (2.75V/Cell) | |||
Ubungakanani (L x W x H) | 7537x498x962 | 537x498x830 | 537x498x697 | |
Malunga.Ubunzima | 240kg | 190kg | 140kg | |
Uhlobo lwetheminali | DIN POST | |||
ITorque yeTheminali | 80 ~ 100 kwi-lbs (9 ~ 11 Nm) | |||
Case Material | SPPC | |||
uKhuseleko olubiyelweyo | IP20 | |||
Ubushushu bokukhutshwa | -4 ~ 131 ºF (-20 ~ 55 ºC) | |||
Ubushushu bentlawulo | -4 ~ 113 ºF (0 ~ 45 ºC) | |||
Ubushushu boGcino | 23 ~ 95 ºF (-5 ~ 35 ºC) | |||
I-BMS yokusika ubushushu obuphezulu | 149 ºF (65 ºC) | |||
Phinda uqhagamshele iTemperature | 131 ºF (55 ºC) | |||
Iziqinisekiso | CE (ibhetri) UN38.3 (ibhetri) UL1642 & IEC62133 (iiseli) | |||
Ukuhlelwa kokuThumela | UN 3480, UDIDI 9 |